elx_mes0449: WorldWide PortName type <type> doesn't conform to IP Profile
DESCRIPTION: In order to run IP, the WorldWide PortName must be of type IEEE
(NAA = 1). This message is displayed if the adapter WWPN doesn't conform with
the standard.
DATA: None
SEVERITY: Error
LOG: Always
ACTION: Turn off the network-on configuration parameter or configure a different
WWPN.
elx_mes0450: Adapter failed to init, mbxCmd <cmd> FARP, mbxStatus
<status>
DESCRIPTION: Adapter initialization failed when issuing a FARP mailbox
command.
DATA: None
SEVERITY: Warning
LOG: LOG_INIT verbose
ACTION: None required.