Emulex LP10000ExDC Instrukcja Użytkownika Strona 229

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 366
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 228
elx_mes0222: Initial FLOGI timeout
DESCRIPTION:The driver sent the initial FLOGI to fabric and never got a response
back.
DATA: None
SEVERITY: Error
LOG: Always
ACTION: Check Fabric configuration. The driver recovers from this and continues
with device discovery.
elx_mes0223: Timeout while waiting for NameServer login
DESCRIPTION: Our login request to the NameServer was not acknowledged
within RATOV.
DATA: None
SEVERITY: Error
LOG: Always
ACTION: Check the fabric configuration. The driver recovers from this and
continues with device discovery.