Sun Blade X6270 Server Module Product Notes 9
ILOM Resolved Issues
TABLE 5 ILOM Resolved Issues
CR Description
6850424 Power Measurements Reported by ILOM Are Lower After Upgrading
Server From ILOM 2.0 to ILOM 3.0.3.35
Issue:
After upgrading your server from ILOM 2.0.x.x to ILOM 3.0.3.35, the
power measurements for permitted_power and available_power are
lower. The amount that the measurements decrease will vary depending on
the number of memory DIMMs that are installed in your server.
Affected Hardware and Software:
Sun Blade X6270 Server Module
ILOM 3.0.3.35
Supplemental Software Releases 1.0, 1.2, and 2.0
Fix Available:
This issue is fixed in Supplemental Software Release 2.0.1 and 2.1.
6862764 BIOS Can Become Corrupted When SP Firmware Is Upgraded Using
Preboot
Issue:
Following an ILOM recovery upgrade using the preboot (uboot) ILOM
recovery method with the .flash ILOM image, the host BIOS software
can become corrupted. This might result in the inability of the host to
correctly power on.
Affected Software:
ILOM 3.0
Supplemental Software Release 2.0
Fix Available:
This issue is fixed in Supplemental Software Release 2.0.1 and 2.1.